Abstract |
In this study, a questionnaire was developed to assess error search and correction tasks, and an analysis was performed on the accuracy of the tasks and the time required for their completion in order to identify the effects of LED light source illumination on visual performance according to changes in a predicted mean vote (PMV) thermal environment. In addition, a subjective evaluation was performed by conducting a survey on the level of visual fatigue experienced during the tasks. In the experiment, four types of PMV thermal environments were established according to PMV values in the temperature range of (17±1-29±1) °C and the humidity range of (50±5-60±5) %, and the LED light source illumination was divided into three types: 400lx, 700lx, and 1000lx. The experimental results confirmed that the accuracy of the error search (LED p value=0.058, PMV*LED p value=0.083) and correction tasks and the time required(LED p value=0.004, PMV p value=0.000) for their completion were affected by changes in both the PMV thermal environment and the LED light source illumination, whereas a significant difference in visual fatigue was observed only in the PMV thermal environment(p value=0.003). Key words: PMV thermal environment, LED source, Ocular fatigue, Visual performance improve. |
|
|
Key Words |