• Home > Journal Search > Past Issues

Past Issues

Endnote RefWorks Scholar's Aid Excel TXT
Vol.14, No.4, 545 ~ 555, 2011
Title
A Evaluation Method for the Effectiveness of Anti-snore Pillow
 
Abstract
In this study, the parameters of Polysomnography (PSG) test, such as total sleep time, snoring time, had been analyzed to evaluate the effectiveness of a developed anti-snore pillow. The developed anti-snore pillow is made up of two polyvinylidene fluoride (PVDF) vibration sensors, pumps, valves, and air bladders. The two PVDF sensors inside the pillow can acquire the sound signals and the algorithm was perfectly designed to extract snoring by removing unwanted noise accurately and automatically. Once the pillow recognizes snore, a pump inside the hardware activates, and a bladder under the neck area inside the pillow will be inflated. The PSG test was used and two volunteers were participated for the study. The parameters of the PSG results were analyzed to evaluate the effectiveness of the anti-snore pillow. The total sleep time of each volunteer was similar on each phase of test, but the snoring time and the longest snoring episode were significantly decreased with the use of anti-snore pillow. The overall results showed excellent possibilities for reducing snoring for the person who snores during sleep by using the anti-snore pillow. The effectiveness of the anti-snore pillow can be evaluated by the PSG test. Moreover, the relationship between each parameter of PSG test and the quality of sleep will be used for further researches.
Key Words
polyvinylidene fluoride, 코골이, 수면 무호흡, 공기 주머니, 코골이 방지 베개, polyvinylidene fluoride, Snoring, Sleep apnea, Air Bladder, anti-snore pillow